Renowned clients trust in our products.







A load-break switch is used to safely and visibly isolate electrical circuits under load—for example, during maintenance and service work on machines and switchgear. Unlike a circuit breaker, it does not trip automatically in the event of a short circuit or overload, but is operated manually.
As an authorized Schneider Electric IAD distributor, BLEMO stocks the FuPacT, ComPacT NSXm, ComPacT NSX, and MasterPact MTZ series. These devices provide safe, manual disconnection of electrical circuits to protect personnel and equipment—ranging from 32 A for small machines to 6,300 A for large power systems.
Load-break switches & main switches
Current range: 32 A – 6,300 A
Series: FuPacT · ComPacT NSXm NA · ComPacT NSX NA · MasterPact
Application: Safe switching and disconnection in industry and mechanical engineering
Load-break switches & main switches
Current range: 32 A – 6,300 A
Series: FuPacT · ComPacT NSXm NA · ComPacT NSX NA · MasterPact
Application: Safe switching and disconnection in industry and mechanical engineering
Whether it’s a new installation, an expansion, or equipment replacement: Our technical sales team will advise you directly—without going through a call center.
More than just technology: BLEMO stands for quality, precision, and sustainable performance.
Time is money – we deliver reliably and on time. Express shipping or courier service is also available upon request.
No call centre,
just real experts to answer your questions.
From product selection to commissioning and problem solving, we are at your side.
Whether training courses, service assignments, or customized solutions—your success is our priority.
The following overview shows which series is suitable for which current range and application:
| Series | FuPacT | ComPacT NSXm NA | ComPacT NSX NA | MasterPact MTZ |
|---|---|---|---|---|
| Current Range | up to 800 A | up to 160 A | up to 630 A | up to 6,300 A |
| Voltage | up to 690 V AC | up to 690 V AC | up to 690 V AC | up to 690 V AC |
| Use Category | AC-22A / AC-23A | AC-22A / AC-23A | AC-22A / AC-23A | AC-22A / AC-23A |
| Typical Applications | Main circuit breakers, Control panel construction | Compact systems, Motor feeders | Industry, Power distribution | Main distribution panels, Power distribution centers |
FuPacT is particularly well-suited for use as a main circuit breaker and in control panel construction for applications up to 800 A.
ComPacT NSXm NA is the compact solution for compact systems and motor feeders up to 160 A—ideal for control cabinets with limited space.
ComPacT NSX NA covers the medium-power range up to 630 A and is primarily used in industrial and power distribution applications.
MasterPact MTZ is designed for main distribution boards and power distribution centers up to 6,300 A, making it the right choice for large power systems.
The duty category specifies the type of load for which the switch is designed: AC-22A is for switching mixed resistive-inductive loads, while AC-23A is for switching motor loads on and off. We would be happy to discuss design details relevant to control panel construction—such as rotary handles, door interlocks, and emergency stop functions—during a personal consultation.
As a certified partner in the field of industrial automation and drives, we have proven expertise in the integration, selection, and commissioning of drive solutions from the Schneider Electric portfolio.
If you would like to learn more about Schneider Electric’s load break switches:
Call us at 06106 / 82 95-0 or send us an email at info@blemo.com
Would you prefer to be contacted by one of our experts? Then use our contact form.
A circuit breaker automatically protects electrical systems against overloads and short circuits—it trips automatically in the event of a fault.
A load break switch, on the other hand, is used for the manual, safe disconnection and switching of electrical circuits, for example during maintenance and service work. To ensure complete protection, these two components are often used in combination.
Yes, many solutions are specifically designed for industrial control cabinets, machines, and power distribution systems. It is important to choose the right solution for your specific application.
Yes. We can help you identify suitable replacement models for older circuit breakers and load break switches—including those from other manufacturers. Our experts will verify technical compatibility and availability, and assist with commissioning.
The choice depends on the required current range and the application: FuPacT for main circuit breakers and control panel construction, ComPacT NSXm for compact systems with limited space, ComPacT NSX for industrial power distribution, and MasterPact MTZ for large main distribution panels up to 6,300 A. We would be happy to advise you on the right series for your project.
After a brief technical consultation—covering aspects such as voltage range, installation dimensions, and usage category—we’ll identify the appropriate replacement model and assist you with delivery and installation. Even for older or discontinued models, we can usually find a compatible solution.
AC-22A and AC-23A are usage categories defined by IEC 60947 that specify the type of load for which a switch is designed. AC-22A is suitable for switching mixed resistive-inductive loads, while AC-23A is specifically designed for switching motor loads with high inrush current.
Your personal contact person